CB-602I W/O CABLE - 2-port CAN bus PC104-Plus module, with isolation, 0 to 55C operating temperature

Deliverytime: 9 - 11 working days (Mo-Fr) *
388,55 EUR
Key points at a glance:
Product Description

Introduction
Moxa’s CB-602I CAN (Controller Area Network) interface boards support the PC/104-Plus interface. Optional DB9 and DB25 connection cables are available for connecting to CAN interface devices. The CB-602I CAN interface boards use the NXP SJA1000 and PCA82C251 transceiver, which provide bus arbitration and error detection. The -40 to 85°C wide operating temperature (CB-602I-T only) and 2 kV isolation make the boards suitable for use in harsh industrial environments.

Serial Interface
- Isolation: 2 kV
- Max. No. of Boards per PC: 8

CAN Interface
- Baudrate: 10/20/50/125/250/500/800/1000 kbps, user-defined
- Connector: 20-pin box header
- No. of Ports: 2

Environmental Limits
- Operating Temperature: Standard Models: 0 to 55°C (32 to 131°F), Wide Temp. Models: -40 to 85°C (-40 to 185°F)
- Storage Temperature (package included): -40 to 85°C (-40 to 185°F)
- Ambient Relative Humidity: 5 to 95% (non-condensing)

Standards and Certifications
- EMC: EN 55032/24
- EMI: CISPR 32, FCC Part 15B Class B

EMS:
- IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
- IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
- IEC 61000-4-4 EFT: Power: 1 kV
- IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
- IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m
- IEC 61000-4-8 PFMF
- IEC 61000-4-11

Declaration
- Green Product: RoHS, CRoHS, WEEE

MTBF
- Time: 248,563 hrs
- Standards: Telcordia (Bellcore), GB

This website uses cookies to ensure you get the best user experience. Privacy Policy