MOXA – 86M-5212U-T – Module for the ioPAC 8600 series, 2-port 2-wire Ethernet switch

Brand:

1.150,65 

Railway, wind power and offshore applications require system reliability and stability, even in harsh environments. Our ruggedised controllers and I/O products are designed for use in extreme conditions and offer versatile data acquisition and control…

When you purchase this item you will receive. 1150 Points
Bulk PriceQuantity (from)Quantity (to)
1.150,65  1 19
1.017,91  20 49
1.009,06  50 199
1.000,21  200
Delivery time: 15-17 Workdays
SKU 387446
EAN 4251877116967
MPN 86M-5212U-T
Categories , , ,
Tags , ,

Railway, wind power and offshore applications require system reliability and stability, even in harsh environments. Our ruggedised controllers and I/O products are designed for use in extreme conditions and offer versatile data acquisition and control functions.

Module for the ioPAC 8600 series, 2-port 2-wire Ethernet switch, -40 to 75°C Operating temperature

Input/output interface
2-wire Ethernet ports
– 2
Isolation
– 3k VDC or 2k Vrms

Digital outputs
Connection
– Spring Euroblock-Terminal
I/O mode
– DO or PWM

Ethernet interface
Connection
– M12 D-coded 2-pin socket
Number of ports
– 2
Standards
– BroadR-Reach® for 10 Mbps and 100 Mbps
– IEEE 802.3 for 10BaseT
– IEEE 802.3u for 100BaseT(X) and 100BaseFX

Performance parameters
Power consumption
– 79.2 mA @ 24 VDC

Physical properties
Dimensions
– 25 x 128.2 x 85.5 mm (0.98 x 5.05 x 3.37 in)
Weight
– Less than 80 g
Cabling
– I/O cable, 16 to 28 AWG

Environmental conditions
Operating temperature
– -40 to 75°C (-40 to 167°F)
Storage temperature (in packaging)
– -40 to 85°C (-40 to 185°F)
Relative humidity
– 5 to 95% (non-condensing)
Altitude
– 2000 m

Standards and certifications
EMC
– EN 55032/24, EN 61000-6-2/-6-4
EMI
– CISPR 32, FCC Part 15B Class A
EMS
– IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
– IEC 61000-4-3 RS: 5100 MHz to 6000 MHz: 3 V/m
– IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV
– IEC 61000-4-5 Surge: Power: 2 kV; Signal: 1 kV
– IEC 61000-4-6 CS: 10 V
– IEC 61000-4-8 PFMF
Railway
– EN 50121-4, EN 50155
Safety
– UL 508
Shock
– IEC 60068-2-27
Vibration
– IEC 60068-2-6

MTBF
Time
– 2,498.942 hours
Standards
– Telcordia SR332